Hard drives/RAID controllers (134 results)
- +8
Delock Host bus adapter USB3.1 Gen2 - NVME PCIe M.2 SSD- USB
- External
- Connectors: 1 x SuperSpeed USB 10 Gbps (USB 3.1 Gen 2) Type-A connector, 1 x 67 pin M.2 Key M slot
- Supports M.2 modules in 2280, 2260 and 2242 format with Key M or Key B M on PCIe (NVMe) basis
- Maximum height of components on the module: 1.5 mm, use of double-sided modules possible
- Mass (LxWxH): approx. 110 x 22 x 6 mm
- +2
NewBroadcom MegaRAID 9520-8i- PCI-Express
- Low profile
- RAID level: 0/1/10/JBOD
- PCIe 4.0 interface for fast data processing
- Low-profile design for easy integration into server housings
- Full-height and low-profile mounting brackets included
- +1
Delock Host bus adapter PCIe x16/x8/x4 – M.2, NVMe, Key M- Connectors: 1 x 67 Pin M.2 Key M Slot 1 x PCI Express x16, V4.0
- Interface: PCIe
- Supports M.2 modules in 2280, 2260, 2242 and 2230 format with Key M or Key B M on PCIe basis
- Bootable, as of UEFI version 2.3.1
- Supports NVM Express (NVMe)
- Dimensions (LxWxH) without PCIe connector: ca. 90 x 24 x 5 mm
- +10
ASUS Host bus adapter Hyper M.2 x16 Gen5 Card- Large heat sink and active fan reduce the temperatures of M.2 SSDs
- Supports up to four NVMe M.2 2242/2260/2280/22110 PCIe 5.0/4.0 M.2 drives
- Connection via PCI-E 5.0 x16 interface, data transfer rate up to 512 Gbps
- Developed for unthrottled transmission speeds
- Use up to four NVMe M.2 SSDs as a bootable NVMe RAID array
- +5
Delock Host bus adapter Controller PCI-Ex4 - M.2 NVME, 1Port- PCI-Express x4
- Full-Height; Low profile
- RAID level: No
- Connectors: internal: 1 x 67 pin M.2 Key M slot 1 x PCI Express x4, V4.0 1 x 2 pin header for LED
- Interface: PCIe, Supports NVM Express (NVMe), Bootable, from UEFI version 2.3.1, OS independent, no driver installation required
- Supports M.2 modules in 2280, 2260 and 2242 format with Key M or Key B M on PCIe basis
- +2
Delock Host bus adapter PCI-Ex4 - M.2 1xNVME Key-M, 1xSATA Key-B- PCI-Express x4
- Full-Height; Low profile
- RAID level: No
- Connectors: internal: 1 x 67 Pin M.2 Key B Slot 1 x 67 Pin M.2 Key M Slot 1 x PCI Express x4, V4.0 1 x SATA 6 Gb/s 7 Pin connector
- Interface: SATA / PCIe (2 or 4 lanes), 3 x LED indicator, bootable, supports NVM Express (NVMe)
- Supports one M.2 module in 22110, 2280, 2260, 2242 and 2230 format with Key B or Key B M on SATA basis and one M.2 module in 22110, 2280, 2260, 2242 and 2230 format with Key M or Key B M on PCIe basis
- +14
ASUS Host bus adapter HYPER M.2 X16 CARD V2- Use up to four NVMe M.2 SSDs as a bootable NVMe RAID array
- Accepts M.2 SSDs in sizes 2242, 2260, 2280 and 22110 (supports PCIe SSDs only)
- Integrated fan and large heatsink provide cooling
- Connection via PCI-E x16 interface, data transfer rate up to 128 Gbps
- New two-phase power solution with up to 14 watts of power per SSD
- Intel VROC-ready and NVMe RAID support on AMD Ryzen Threadripper
- +5
Highpoint Host bus adapter Rocket 1204 PCI-Ex8v3 - 4x M.2 NVMe- PCI-Express x8
- Full-Height
- RAID level: 0
- Fully compliant with Industry standard PCIe 3.0 Slots; no-Bifurcation dependency or need for a specific brand/model of motherboard
- Integrated, High-Performance, Intelligent PCIe Switch technology can allocate up to x4 dedicated lanes to each M.2 Slot
- Silent, Fan-less Cooling System
- +3
Highpoint RAID controller SSD6202A PCI-Ex8v3 - 2x M.2 NVMe, bootable- PCI-Express x8
- Low profile
- RAID level: 0/1/Single
- Wide Spectrum of Bootable OS Support
- UEFI, CLI & WebGUI RAID Configuration & Management
- SHI – Storage Health Inspector; Active SMART, temperature & TBW monitoring
- +3
Delock SATA controller PCI-Ex4- 6x SATA internal- Internal interfaces: 6 x SATA 6 Gb/s 7 pin connector
- 1 x PCI Express x4 (2-lane), V3.0,
- 6x 2 pin header for LED
- Supports Native Command Queing (NCQ), S.M.A.R.T, TRIM, DevSleep, SATA Port Multiplier
- Hot plug capable
- Chipset: Asmedia ASM1166
- +4
Delock SATA controller PCI-Ex2- 10x SATA3 internal- 10x SATA 6 Gb/s 7-pin connector
- 1x PCI Express x2, V2.0
- 12x 2 pin header for LED
- Supports Native Command Queuing (NCQ)
- Supports ATA, ATAPI
- Native AHCI support required
- +7
Delock Host bus adapter 2 Port SATA PCIe Map- PCI-Express x1
- Low profile; Full-Height
- RAID level: No
- Connectors internal: 2 x SATA 6 Gb/s 7 pin connector, 1 x PCI Express x1, V3.0
- Hot swap and bootable
- +10
Delock Host bus adapter PCI Express x1 to M.2 Key M Adapter- PCI-Express x1
- M.2
- RAID level: No
- Supports NVM Express (NVMe)
- Bootable
- Plug & Play
- +3
Delock Host bus adapter PCI-Express x16 - 4 x NVMe M.2 Key M 110 mm- PCI-Express x16
- Low profile; Full-Height
- RAID level: No
- Connectors: internal: 4 x 67 Pin M.2 Key M Slot , 1 x PCI Express x16, V4.0
- Interface: PCIe, supports M.2 modules in 22110, 2280 and 2260 format with Key M or Key B M on PCIe (NVMe) basis
- Maximum height of components on the module: 1.5 mm, use of double-sided modules possible, supports NVM Express (NVMe)
- +4
Delock Host bus adapter PCI-E-x16, 4x M.2 Key-M. NVME Bifurcation- PCI-Express x16
- Full-Height
- RAID level: No
- +2
Broadcom Host bus adapter 9500-8i- PCI-Express
- Full-Height; Low profile
- RAID level: No
- Connects up to 1024 SAS/SATA devices or 32 NVMe devices
- Support critical applications with the bandwidth of PCIe 4.0 connectivity
- Universal Bay Management (UBM) Ready
- +10
Delock Host bus adapter PCI Express x16 - 1x NVMe M.2 Key M- PCI-Express x1; PCI-Express x16; PCI-Express x4; PCI-Express x8
- Low profile
- RAID level: No
- Supports S.M.A.R.T. and TRIM
- 1x LED indicator for power and activity
- 7x RGB LED for automatic color gradient
- +11
Delock Host bus adapter PCI Express x8 - 2x U.2 NVMe SFF-8639- PCI-Express x8
- Full-Height
- RAID level: No
- Connectors: internal: 2 x U.2 SFF-8639 socket, 1 x PCI Express x8, V4.0
- Supports NVM Express (NVMe)
- 2 x LED display for power and activity
- +4
Delock Host bus adapter SATA M.2 SSD – M.2 NVMe SSD- SATA, Supports NVM Express (NVMe)
- Interface: SATA / PCIe (2 or 4 lanes)
- Connectors: 1 x SATA 6 Gb/s 22 pin male (for SATA SSDs), 1 x 36 pin SFF-8643 female (for PCIe SSDs 2 or 4 lanes), 1 x 67 pin M.2 Key M slot
- Suitable for M.2 modules in the format: 2280, 2260, 2242 and 2230 with Key M or Key B M on PCIe base or SATA base
- Maximum height of components on the module: 1.5 mm, use of double-sided modules possible
- Mass (LxWxH): approx. 145 x 50 x 16 mm
- +8
Delock SATA controller PCI-Ex4 - 5x SATA3 internal- PCI-Express x4
- Low profile; Full-Height
- RAID level: No
- +1
Delock Host bus adapter 2x NVME M.2 SSDs, PCI-Ex16, bootable- Connection via PCIe 3.0 x16
- Two M.2 slots, one of which is bootable
- Supports M.2 modules in 2280, 2260, 2242 and 2230 format with Key M or Key B M on PCIe basis
- Supports NVM Express (NVMe), data transfer rate up to 32 Gbps
- Large heat sink and 40mm fan for effective cooling
- +4
Delock Host bus adapter PCI-Ex16v4 - M.2 Key-B, M.2 Key-M, mSATA- PCI-Express x16
- Low profile
- RAID level: No
- +10
Delock Host bus adapter Controller PCIe – M.2, NVMe, up to 110 mm- PCI-Express x4
- Low profile; Full-Height
- RAID level: No
- Connectors: internal: 1 x 67 pin M.2 Key M slot 1 x PCI Express x4, V4.0 1 x 2 pin LED header
- Interface: PCIe
- Supports M.2 modules in 22110, 2280, 2260 and 2242 format with Key M or Key B M on PCIe basis
- +5
Delock Host bus adapter 2x NVME M.2 SSDs, PCI-Ex8, bootable- PCI-Express x8
- Low profile
- RAID level: No
- +1
Highpoint RAID controller SSD7202 2x M.2 NVMEx4v3, PCI-Ex8- PCI-Express x8
- Low profile
- RAID level: 0/1/Single
- Up to two commercially available M.2 MLC, TLC & QLC NVMe SSD's, SSD Form Factor: 2242/2260/2280 (supports single & double sided)
- Flexible solution: compatible with PCIe x8 and x16 slots
- Low profile bootable NVMe solution for Linux & Windows
- +2
Adaptec Host bus adapter 4 Port SATA3/SAS3 1100-4i- 4 internal SAS/SATA ports in low-profile MD2 form factor
- PCIe 3.0 x8 host interface, 1x SFF-8643 connector
- 12 Gbps SAS data rates with mini SASHD connectors
- Quality and reliability through unified, robust smart storage stack
- High bandwidth, low latency and best I/O performance
- Proven compatibility and seamless integration with existing Microsemi Adaptec solutions
- +6
Delock SATA controller 5 Port SATA Kontroller PCI-Express-x4- PCI-Express
- Low profile
- RAID level: No
- Internal connectors: 5 x SATA 6 Gb/s 7 pin male, 1 x PCI Express x4, V3.0
- Hot-Swap
- Bootable
- +1
Delock Host bus adapter PCI-Express x4 - 1x U.3 SFF-8639- PCI-Express x4
- Full-Height
- RAID level: No
- For 2.5″ U.3 NVMe SSD
- Supports NVM Express (NVMe)
- +3
Highpoint RAID controller SSD6204A PCI-Ex8v3 - 4x M.2 NVMe, bootable- PCI-Express x8
- Full-Height
- RAID level: 0/1/Single
- Wide Spectrum of Bootable OS Support
- UEFI, CLI & WebGUI RAID Configuration & Management
- SHI – Storage Health Inspector; Active SMART, temperature & TBW monitoring
- +2
Delock Host bus adapter PCI-Express x16v3 to 5xM.2 Key-B, SATA- PCI-Express x16
- Full-Height; Low profile
- RAID level: No
- Data transfer rate up to 6 Gb/s
- Hot-Swap
- Bootable
- +2
SaleHighpoint Host bus adapter Rocket 1508 PCI-Ex16v4 - 8x M.2 NVMe- PCI-Express x16
- Full-Height
- RAID level: 0/JBOD
- Up to 8 NVMe SSDs
- Integrated, Intelligent, Next-Gen PCIe 4.0 Switch technology ensures up to PCIex4 lanes are allocated to each M.2 Slot
- Gen4 Hyper Cooling Solution
- +1
Delock SATA controller PCI-Express x1 - 2x SATA 2.5"- PCI-Express x1
- Full-Height
- RAID level: No
- Connectors: internal: 1 x PCI Express x1, V2.0 2 x SATA 22 pin receptacle
- Chipset: Asmedia ASM1061
- Suitable for 2.5″ SATA HDD / SSD: SATA HDD / SSD up to 6 Gb/s supports 5 V HDD / SSD
- +5
Delock Host bus adapter PCI Express x16 - 4x NVMe M.2 Key M- PCI-Express x16
- Full-Height; Low profile
- RAID level: No
- Maximum height of components on the module: 1.5 mm, use of double-sided modules possible
- Data transfer rate up to 32 Gbps
- Supports NVM Express (NVMe)
- +3
Highpoint Host bus adapter Rocket R710L 8 channels, 2x SFF-8643- PCI-Express x8
- Low profile
- RAID level: No
- +8
Delock Host bus adapter Controller PCI-Express-X4 - U.2, 2.5"- PCI-Express x4
- Full-Height
- RAID level: No
- Connectors: internal: 1 x U.2 SFF-8639 female 1 x PCI Express x4, V4.0 1 x 2 pin LED header
- For 2.5″ NVMe SSD
- Supports NVM Express (NVMe)
- +5
Delock Host bus adapter Controller PCI-ex4 - M.2, 2Port- Expansion with two M.2 slots
- For M.2 modules in 22110, 2280, 2260, 2242 and 2230 format with Key B or Key B M on SATA basis
- Connectors: 2x 67 pin M.2 Key B slot, 1x PCI Express x1, 2x SATA 6 Gb/s 7 pin female connector
- Maximum height of components on the module: 1.5 mm
- Use of double-sided modules possible
- +1
Delock RAID controller PCI-Ex1- 2x SATA Chipset ASM1061R- 2x SATA 6 Gb/s 7-pin connector
- 1x PCI Express x1, V2.0
- 2x 2 pin header for LED
- Supports Native Command Queuing (NCQ)
- Chipset: Asmedia ASM1061R
- Supports RAID 0, 1, SPAN
- +3
Broadcom MegaRAID 9520-2M2- PCI-Express x8
- Low profile
- RAID level: 0/1/10
- Including low-profile slot bracket
- +3
Delock SATA controller PCI-Ex1- 4x SATA Marvell 88SE9215 chipset- 4x SATA 6 Gb/s 7-pin connector
- 1x PCI Express x1, V2.0
- 2x 2 pin header for LED
- Supports Native Command Queuing (NCQ)
- Chipset: Marvell 88SE9215
- +4
Delock Host bus adapter PCIe x1 card to 2x M.2 Key B bootable- PCI-Express x1
- Full-Height
- RAID level: No
- Internal connectors: 2 x 67 pin M.2 Key B slot, 1 x PCI Express x1, V3.0
- Supports M.2 modules in 2280, 2260, 2242 and 2230 format with Key B or Key B M on SATA basis
- +5
Delock SATA controller PCI-Ex4 - 3xSATA3, 2xM.2 Key-B- PCI-Express x4
- Full-Height; Low profile
- RAID level: No
- +1
Adaptec Host bus adapter 36Port SAS-Expander- 36 ports (28 internal / 8 external)
- 12 Gbit/s throughput per port
- Low profile MD2 form factor
- Backward compatible with 6 Gbps SAS and SATA drives
- Requires SAS controller with at least one SFF-8643 connector
- Compatible with SAS3 and SAS2 controllers from all manufacturers
- +1
Highpoint Host bus adapter Rocket R720 16 channels, SAS3/SATA3- PCI-Express x8
- Half-Height
- RAID level: 0/1/10/JBOD
- +3
Highpoint RAID controller SSD7105 PCI-Ex16v3 - 4x M.2 NVMe, bootable- PCI-Express x16
- Full-Height
- RAID level: 0/1/10/Single
- Comprehensive NVMe Boot Support for Linux and Windows
- Up to 32TB capacity per controller
- Low-Noise Hyper-Cooling Solution with Full fan control
- +5
Highpoint RAID controller SSD7505 PCI-x4v4 M.2, PCI-Ex16v4, bootable- PCI-Express x16
- Full-Height
- RAID level: 0/1
- Up to 32TB capacity per controller
- Low noise hyper-cooling solution
- Integrated SSD TBW and temperature monitoring function
- +1
Delock Host bus adapter Controller PCI-Ex1 - M.2, 2Port- Supports M.2 NGFF modules in 22110, 2280, 2260, 2242, 2230 format
- For modules with Key M or B M on SATA or USB basis
- Maximum height of components on the module: 1.35 mm
- Two-sided assembly possible
- OS independent, no driver installation required
- Bootable (SATA), data transfer rate of up to 6 Gbps

